Overview
The MC100EP08DTR2G, produced by onsemi, is a high-performance 3.3 V/5 V ECL (Emitter-Coupled Logic) 2-Input Differential XOR/XNOR gate. This device is part of the 100 Series, which includes temperature compensation, making it ideal for applications requiring the fastest AC performance available. The MC100EP08 is available in SOIC-8 and TSSOP-8 packages and is Pb-Free, Halogen Free, and RoHS compliant.
Key Specifications
Parameter | Condition | Value | Unit |
---|---|---|---|
Propagation Delay | Typical | 250 ps | |
Maximum Frequency | Typical | > 3 GHz | |
PECL Mode Operating Range | VCC = 3.0 V to 5.5 V, VEE = 0 V | ||
NECL Mode Operating Range | VCC = 0 V, VEE = −3.0 V to −5.5 V | ||
Power Supply Current (PECL Mode) | VCC = 5.0 V, VEE = 0 V | 20 - 36 mA | |
Output HIGH Voltage (PECL Mode) | VCC = 5.0 V, VEE = 0 V | 3865 - 4115 mV | |
Output LOW Voltage (PECL Mode) | VCC = 5.0 V, VEE = 0 V | 3065 - 3315 mV | |
Input HIGH Voltage (Single-Ended) | VCC = 5.0 V, VEE = 0 V | 3790 - 4115 mV | |
Input LOW Voltage (Single-Ended) | VCC = 5.0 V, VEE = 0 V | 3065 - 3390 mV | |
Operating Temperature Range | −40 to +85 °C | ||
Storage Temperature Range | −65 to +150 °C |
Key Features
- Differential XOR/XNOR gate with high-speed ECL logic
- Propagation delay of 250 ps typical
- Maximum frequency greater than 3 GHz typical
- PECL and NECL mode operation
- Open input default state with safety clamp on inputs
- Q output defaults LOW with inputs open or at VEE
- Pb-Free, Halogen Free, and RoHS compliant
- Internal input pulldown and pullup resistors
- ESD protection: Human Body Model > 4 kV, Machine Model > 200 V, Charged Device Model > 2 kV
Applications
- High-speed digital logic circuits
- Telecommunication systems requiring fast data processing
- Data transmission and reception systems
- Clock distribution and synchronization
- High-frequency signal processing
Q & A
- What is the typical propagation delay of the MC100EP08?
The typical propagation delay is 250 ps.
- What are the operating voltage ranges for PECL and NECL modes?
For PECL mode, VCC = 3.0 V to 5.5 V with VEE = 0 V. For NECL mode, VCC = 0 V with VEE = −3.0 V to −5.5 V.
- What is the maximum frequency of operation for the MC100EP08?
The maximum frequency is greater than 3 GHz typical.
- What happens to the Q output when the inputs are open or at VEE?
The Q output will default LOW.
- Is the MC100EP08 RoHS compliant?
Yes, the device is Pb-Free, Halogen Free, and RoHS compliant.
- What is the operating temperature range of the MC100EP08?
The operating temperature range is −40 to +85 °C.
- What is the storage temperature range of the MC100EP08?
The storage temperature range is −65 to +150 °C.
- Does the MC100EP08 have ESD protection?
Yes, it has ESD protection with ratings of > 4 kV for Human Body Model, > 200 V for Machine Model, and > 2 kV for Charged Device Model.
- What are the typical output voltages for PECL mode?
The output HIGH voltage is 3865 - 4115 mV, and the output LOW voltage is 3065 - 3315 mV.
- What are the input voltage ranges for PECL mode?
The input HIGH voltage is 3790 - 4115 mV, and the input LOW voltage is 3065 - 3390 mV.