Overview
The MUR120GP-TP is a 1.0 Amp Glass Passivated Super Fast Recovery Rectifier manufactured by Micro Commercial Components (MCC). This component is designed for high-efficiency applications and features a peak reverse voltage of 200V, making it suitable for a variety of power management and rectification needs.
Key Specifications
Parameter | Value |
---|---|
Peak Reverse Voltage (V) | 200V |
Maximum RMS Voltage (V) | 140V |
Maximum DC Blocking Voltage (V) | 200V |
Average Forward Current (I_F(AV)) | 1.0A |
Peak Forward Surge Current (I_FSM) | 35A (8.3ms, Half Sine) |
Maximum Instantaneous Forward Voltage (V_F) | 1.35V at I_F = 1.0A, T_J = 25°C |
Maximum Reverse Recovery Time (t_rr) | 60ns at I_F = 0.5A, I_R = 1.0A, I_rr = 0.25A |
Maximum DC Reverse Current (I_R) | 5.0μA at T_J = 25°C, 50μA at T_J = 150°C |
Operating Junction Temperature Range | -65°C to +150°C |
Storage Temperature Range | -65°C to +150°C |
Typical Thermal Resistance (R_th(J-A)) | 60°C/W |
Package Type | DO-41 |
Key Features
- Super Fast Switching Speed for High Efficiency
- Halogen Free Available Upon Request (Add Suffix '-HF')
- Epoxy Meets UL 94 V-0 Flammability Rating
- Lead Free Finish/RoHS Compliant (Note: 'P' Suffix Designates Compliant)
- Passivated for Enhanced Reliability
- High Temperature Solder Exemptions Applied (See EU Directive Annex 7a)
Applications
The MUR120GP-TP is suitable for various applications requiring high-efficiency rectification, including:
- Power Supplies and DC-DC Converters
- Switch-Mode Power Supplies
- High-Frequency Inverters
- Free-Wheeling Diodes in Motor Control Circuits
- General Purpose Rectification in Industrial and Consumer Electronics
Q & A
- What is the peak reverse voltage of the MUR120GP-TP?
The peak reverse voltage of the MUR120GP-TP is 200V.
- What is the average forward current rating of the MUR120GP-TP?
The average forward current rating is 1.0A.
- Is the MUR120GP-TP RoHS compliant?
- What is the maximum reverse recovery time of the MUR120GP-TP?
The maximum reverse recovery time is 60ns at specified conditions.
- What is the operating junction temperature range of the MUR120GP-TP?
The operating junction temperature range is -65°C to +150°C.
- Does the MUR120GP-TP meet any specific flammability standards?
- Can the MUR120GP-TP be used in high-frequency applications?
- What is the typical thermal resistance of the MUR120GP-TP?
The typical thermal resistance is 60°C/W junction to ambient.
- Is the MUR120GP-TP available in a halogen-free version?
- What package type does the MUR120GP-TP come in?
The MUR120GP-TP comes in a DO-41 package.