Overview
The BTA06-600BRG is a 6A standard triac from STMicroelectronics, designed for general purpose AC switching applications. It is available in both through-hole and surface-mount packages, making it versatile for various uses. This triac is part of the BTA06 and BTB06 series, which are suitable for ON/OFF functions in applications such as static relays, heating regulation, induction motor starting circuits, and phase control operations in light dimmers and motor speed controllers. The BTA06-600BRG features a voltage-insulated tab rated at 2500V RMS, complying with UL standards, and is RoHS compliant with an Ecopack2 grade.
Key Specifications
Parameter | Value | Unit |
---|---|---|
IT(RMS) | 6 | A |
VDRM/VRRM | 600 | V |
IGT (Q1) | 5 to 50 | mA |
ITSM (Non-repetitive surge peak on-state current) | 60 A (F = 50 Hz, t = 20 ms) | A |
dI/dt (Critical rate of rise of on-state current) | 50 A/µs | A/µs |
IGM (Peak gate current) | 4 A | A |
PG(AV) (Average gate power dissipation) | 1 W | W |
Tstg (Storage junction temperature range) | -40 to +150 | °C |
Tj (Operating junction temperature range) | -40 to +125 | °C |
Rth(j-c) (Junction to case thermal resistance) | 1.8 °C/W (TO-220AB), 2.7 °C/W (TO-220AB Insulated) | °C/W |
Rth(j-a) (Junction to ambient thermal resistance) | 60 °C/W (TO-220AB), 60 °C/W (TO-220AB Insulated) | °C/W |
Key Features
- Voltage Insulation: The BTA06 series provides a voltage-insulated tab rated at 2500V RMS, complying with UL standards.
- High Commutation Performance: Snubberless and logic level versions are recommended for use on inductive loads due to their high commutation performances.
- Package Options: Available in both through-hole and surface-mount packages (TO-220AB).
- RoHS Compliance: The component is RoHS compliant with an Ecopack2 grade.
- Wide Application Range: Suitable for static relays, heating regulation, induction motor starting circuits, and phase control operations in light dimmers and motor speed controllers.
Applications
- Static Relays: Used as an ON/OFF function in static relay applications.
- Heating Regulation: Suitable for heating control systems.
- Induction Motor Starting Circuits: Used in the starting circuits of induction motors.
- Light Dimmers and Motor Speed Controllers: Used for phase control operations in light dimmers and motor speed controllers.
Q & A
- What is the maximum RMS on-state current of the BTA06-600BRG?
The maximum RMS on-state current is 6 A.
- What is the maximum voltage rating (VDRM/VRRM) of the BTA06-600BRG?
The maximum voltage rating is 600 V.
- What is the gate trigger current (IGT) range for the BTA06-600BRG?
The gate trigger current range is 5 to 50 mA.
- What are the thermal resistance values for the BTA06-600BRG?
The junction to case thermal resistance is 1.8 °C/W (TO-220AB) and 2.7 °C/W (TO-220AB Insulated), and the junction to ambient thermal resistance is 60 °C/W for both packages.
- Is the BTA06-600BRG RoHS compliant?
Yes, the BTA06-600BRG is RoHS compliant with an Ecopack2 grade.
- What are the typical applications of the BTA06-600BRG?
Typical applications include static relays, heating regulation, induction motor starting circuits, and phase control operations in light dimmers and motor speed controllers.
- What is the storage junction temperature range for the BTA06-600BRG?
The storage junction temperature range is -40 to +150 °C.
- What is the operating junction temperature range for the BTA06-600BRG?
The operating junction temperature range is -40 to +125 °C.
- What is the average gate power dissipation for the BTA06-600BRG?
The average gate power dissipation is 1 W.
- What is the critical rate of rise of on-state current (dI/dt) for the BTA06-600BRG?
The critical rate of rise of on-state current is 50 A/µs.