Overview
The ACS108-5SA-AP, produced by STMicroelectronics, is a high-performance AC switch that belongs to the AC switch range built with A.S.D.® technology. This device is capable of controlling a load of up to 0.8 A and features an overvoltage crowbar structure to absorb the inductive turn-off energy. It also includes a gate level shifter driver to separate the digital controller from the main switch, which is triggered by a negative gate current flowing out of the gate pin.
Key Specifications
Parameter | Value | Unit |
---|---|---|
IT(RMS) | 0.8 | A |
VDRM, VRRM | 600 and 800 | V |
IGT | 10 | mA |
ITSM (Non repetitive surge peak on-state current) | 13.7 (F = 60 Hz, t = 16.7 ms) | A |
I²t Value for fusing | 1.1 | A²s |
dI/dt (Critical rate of rise of on-state current) | 100 | A/µs |
VPP (Non repetitive mains peak mains voltage) | 2 kV | V |
IGM (Peak gate current) | 1 | A |
VGM (Peak positive gate voltage) | 10 | V |
PG(AV) (Average gate power dissipation) | 0.1 | W |
Tstg (Storage junction temperature range) | -40 to +150 | °C |
Tj (Operating junction temperature range) | -30 to +125 | °C |
Package | TO-92 | |
Grade | Industrial | |
RoHS Compliance Grade | Ecopack2 |
Key Features
- Enables equipment to meet IEC 61000-4-5 surge with overvoltage crowbar technology.
- High noise immunity against static dV/dt and IEC 61000-4-4 burst.
- No need for external protection snubber or varistor.
- Reduces component count by up to 80% and interfaces directly with the micro-controller.
- Common package tab connection supports connection of several alternating current switches on the same cooling pad.
- VCL gives headroom before clamping then crowbar action.
Applications
- Alternating current on/off static switching in appliances and industrial control systems.
- Driving low power high inductive or resistive loads such as relays, valves, solenoids, dispensers, pumps, fans, low power motors, and door locks.
- Lamp control.
Q & A
- What is the maximum load current the ACS108-5SA-AP can control?
The ACS108-5SA-AP can control a load of up to 0.8 A.
- What is the purpose of the overvoltage crowbar structure in the ACS108-5SA-AP?
The overvoltage crowbar structure is designed to absorb the inductive turn-off energy and protect against surge voltages.
- Does the ACS108-5SA-AP require external protection components like snubbers or varistors?
No, the ACS108-5SA-AP does not require external protection snubbers or varistors.
- How does the ACS108-5SA-AP improve noise immunity?
The device offers high noise immunity against static dV/dt and IEC 61000-4-4 burst.
- What are the benefits of the common package tab connection in the ACS108-5SA-AP?
The common package tab connection supports the connection of several alternating current switches on the same cooling pad.
- What is the significance of VCL in the ACS108-5SA-AP?
VCL provides headroom before clamping and then initiates crowbar action, protecting against overvoltages.
- What are the typical applications of the ACS108-5SA-AP?
Typical applications include alternating current on/off static switching in appliances and industrial control systems, and driving low power high inductive or resistive loads.
- What is the operating junction temperature range of the ACS108-5SA-AP?
The operating junction temperature range is -30 to +125 °C.
- What is the storage junction temperature range of the ACS108-5SA-AP?
The storage junction temperature range is -40 to +150 °C.
- What package type is the ACS108-5SA-AP available in?
The ACS108-5SA-AP is available in the TO-92 package.