Overview
The MPXV5100GP is a state-of-the-art monolithic silicon pressure sensor produced by NXP USA Inc. This piezoresistive transducer is designed for a wide range of applications, particularly in medical and industrial fields. It offers differential, gauge, and absolute pressure sensing capabilities, making it versatile for various use cases. The sensor combines advanced micromachining techniques, thin-film metallization, and bipolar processing to provide accurate and high-level output signals.
Key Specifications
Characteristic | Symbol | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Maximum Pressure | Pmax | 400 | kPa | ||
Storage Temperature | Tstg | -40 | 125 | °C | |
Operating Temperature | TA | -40 | 125 | °C | |
Pressure Range (Gauge, Differential) | POP | 0 | 115 | kPa | |
Supply Voltage | VS | 4.75 | 5.0 | 5.25 | VDC |
Supply Current | IO | 7.0 | 10 | mAdc | |
Minimum Pressure Offset (0 to 85 °C) | 470 pF |
Key Features
- Ideally suited for microprocessor or microcontroller-based systems due to its ratiometric output.
- Patented silicon shear stress strain gauge technology for high accuracy.
- Available in differential, gauge, and absolute pressure configurations.
- Durable epoxy unibody element for robustness.
- Easy-to-use chip carrier option for convenient integration.
- Compact 8-pin SOIC package (SO8) with gull wing, side port configuration.
Applications
- Patient monitoring in medical devices.
- Process control in industrial settings.
- Pump and motor control systems.
- Pressure switching applications.
Q & A
- What is the maximum pressure rating of the MPXV5100GP?
The maximum pressure rating is 400 kPa.
- What is the operating temperature range of the MPXV5100GP?
The operating temperature range is -40°C to +125°C.
- What are the supply voltage and current specifications?
The supply voltage is 4.75 to 5.25 VDC, and the supply current is typically 7.0 mA with a maximum of 10 mA.
- What types of pressure configurations are available for the MPXV5100GP?
The sensor is available in differential, gauge, and absolute pressure configurations.
- What is the package type and configuration of the MPXV5100GP?
The package type is an 8-pin SOIC (SO8) with a gull wing, side port configuration.
- Is the MPXV5100GP suitable for microcontroller-based systems?
- What are some typical applications of the MPXV5100GP?
Typical applications include patient monitoring, process control, pump and motor control, and pressure switching.
- Does the MPXV5100GP have any environmental certifications?
- How does the temperature affect the output of the MPXV5100GP?
The output is affected by a temperature multiplier, which is a linear response from 0°C to -40°C and from 85°C to 125°C.
- What is the pressure error band for the MPXV5100GP?
The pressure error band is ±2.5 kPa over the operating range.