Overview
The MPX5100AP is a state-of-the-art monolithic silicon pressure sensor produced by NXP USA Inc. This piezoresistive transducer is designed for a wide range of applications, particularly those employing microprocessor or microcontroller-based systems. The sensor combines advanced micromachining techniques, thin-film metallization, and bipolar processing to provide an accurate, high-level analog output signal proportional to the applied pressure.
Key Specifications
Characteristic | Symbol | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Pressure Range | P | 0 | - | 115 | kPa (2.2 to 16.7 psi) |
Supply Voltage | VS | 4.75 | 5.0 | 5.25 | VDC |
Supply Current | IO | - | - | 10 | mAdc |
Maximum Pressure | PMAX | - | - | 400 | kPa |
Storage Temperature | TSTG | -40 | - | 125 | °C |
Operating Temperature | TA | -40 | - | 125 | °C |
Pressure Error (max) | - | - | - | ± 2.5 kPa (0 to 100 kPa) | - |
Key Features
- Ideally suited for microprocessor or microcontroller-based systems.
- Patented silicon shear stress strain gauge.
- Available in absolute, differential, and gauge configurations.
- Durable epoxy unibody element.
- Easy-to-use chip carrier option.
- Maximum error of 2.5% over the temperature range of 0 to 85°C.
Applications
- Patient monitoring.
- Process control.
- Pump/motor control.
- Pressure switching.
- White goods.
Q & A
- What is the MPX5100AP pressure sensor?
The MPX5100AP is a monolithic silicon pressure sensor designed for various applications, particularly those using microprocessor or microcontroller-based systems.
- What are the pressure range and units for the MPX5100AP?
The pressure range is from 0 to 115 kPa, which is equivalent to 0 to 16.7 psi.
- What is the supply voltage range for the MPX5100AP?
The supply voltage range is from 4.75 V to 5.25 VDC.
- What is the maximum supply current for the MPX5100AP?
The maximum supply current is 10 mA DC.
- What are the storage and operating temperature ranges for the MPX5100AP?
The storage temperature range is -40°C to +125°C, and the operating temperature range is also -40°C to +125°C.
- What is the maximum pressure limit for the MPX5100AP?
The maximum pressure limit is 400 kPa.
- What are the typical applications of the MPX5100AP?
Typical applications include patient monitoring, process control, pump/motor control, pressure switching, and white goods.
- What are the key features of the MPX5100AP?
- What is the maximum error over the specified temperature range for the MPX5100AP?
The maximum error is 2.5% over the temperature range of 0 to 85°C.
- How does the MPX5100AP provide its output signal?
The MPX5100AP provides an accurate, high-level analog output signal that is proportional to the applied pressure.