Overview
The ISO1042DWV is a galvanically-isolated Controller Area Network (CAN) transceiver produced by Texas Instruments. It meets the specifications of the ISO 11898-2:2016 standard and is designed to provide robust and reliable communication in harsh industrial environments. The device offers ±70-V DC bus fault protection and a ±30-V common-mode voltage range, ensuring high reliability and protection against electrical faults. It supports both classic CAN up to 1 Mbps and CAN FD (Flexible Data Rate) up to 5 Mbps, enabling faster data transfer. The ISO1042DWV is available in an 8-pin SOIC (DWV) package and operates over a wide ambient temperature range of –40°C to +125°C.
Key Specifications
Parameter | Value | Unit |
---|---|---|
Package | SOIC (DWV) | - |
Pins | 8 | - |
Operating Temperature Range | -40 to 125 | °C |
Data Rate (Classic CAN) | Up to 1 Mbps | - |
Data Rate (CAN FD) | Up to 5 Mbps | - |
Loop Delay | 152 ns | - |
DC Bus Fault Protection Voltage | ±70 V | - |
HBM ESD Tolerance on Bus Pins | ±16 kV | - |
Common-Mode Voltage Range | ±30 V | - |
VCC1 Voltage Range | 1.71 V to 5.5 V | - |
VCC2 Voltage Range | 4.5 V to 5.5 V | - |
Isolation Withstand Voltage | 5000 VRMS | - |
Key Features
- Meets the ISO 11898-2:2016 physical layer standard
- Supports classic CAN up to 1 Mbps and CAN FD up to 5 Mbps
- Low loop delay: 152 ns
- Protection features:
- DC bus fault protection voltage: ±70 V
- HBM ESD tolerance on bus pins: ±16 kV
- Driver Dominant Time Out (TXD DTO)
- Undervoltage protection on VCC1 and VCC2
- Common-Mode Voltage Range: ±30 V
- Ideal passive, high impedance bus terminals when unpowered
- High CMTI: 100 kV/µs
- Supports 1.8-V, 2.5-V, 3.3-V, and 5.0-V logic interface to the CAN controller
- Robust Electromagnetic Compatibility (EMC):
- System-level ESD, EFT, and surge immunity
- Low emissions
- Ambient Temperature Range: –40°C to +125°C
- Safety-related certifications:
- 7071-VPK VIOTM and 1500-VPK VIORM per DIN VDE V 0884-11:2017-01
- 5000-V RMS Isolation for 1 Minute per UL 1577
- IEC 60950-1, IEC 60601-1, and EN 61010-1 certifications
- CQC, TUV, and CSA certifications
Applications
- AC and servo drives
- Solar inverters
- PLC and DCS communication modules
- Elevators and escalators
- Industrial power supplies
- Battery charging and management
Q & A
- What is the ISO1042DWV and what standard does it meet?
The ISO1042DWV is a galvanically-isolated CAN transceiver that meets the ISO 11898-2:2016 physical layer standard.
- What data rates does the ISO1042DWV support?
The device supports classic CAN up to 1 Mbps and CAN FD up to 5 Mbps.
- What is the DC bus fault protection voltage of the ISO1042DWV?
The device offers ±70-V DC bus fault protection.
- What is the common-mode voltage range of the ISO1042DWV?
The common-mode voltage range is ±30 V.
- What are the operating temperature ranges for the ISO1042DWV?
The device operates over a temperature range of –40°C to +125°C.
- What are the key protection features of the ISO1042DWV?
The device features DC bus fault protection, HBM ESD tolerance, Driver Dominant Time Out (TXD DTO), and undervoltage protection on VCC1 and VCC2.
- What are the safety-related certifications for the ISO1042DWV?
The device has certifications such as 7071-VPK VIOTM and 1500-VPK VIORM, 5000-V RMS Isolation, IEC 60950-1, IEC 60601-1, EN 61010-1, CQC, TUV, and CSA.
- What are some typical applications for the ISO1042DWV?
Typical applications include AC and servo drives, solar inverters, PLC and DCS communication modules, elevators and escalators, industrial power supplies, and battery charging and management.
- What is the isolation withstand voltage of the ISO1042DWV?
The device has an isolation withstand voltage of 5000 VRMS.
- What are the voltage ranges for VCC1 and VCC2?
VCC1 ranges from 1.71 V to 5.5 V, and VCC2 ranges from 4.5 V to 5.5 V.