Overview
The DCV010512DP-U/700, part of the DCV01 series from Texas Instruments, is a miniature, 1-W, 1500-Vrms isolated, unregulated DC/DC converter module. This device is designed to provide up to 1 W of isolated output power from a 5-V, 15-V, or 24-V input source. The DCV01 series is characterized by its high efficiency, typically up to 86%, achieved through advanced BiCMOS and DMOS process technology and highly integrated packaging. These converters are specified for operational isolation only and are not intended for safety isolation circuits requiring reinforced isolation.
Key Specifications
Parameter | Minimum | Typical | Maximum | Unit |
---|---|---|---|---|
Input Voltage (5-V input devices) | 4.5 | 5 | 5.5 | V |
Input Voltage (15-V input devices) | 13.5 | 15 | 16.5 | V |
Input Voltage (24-V input devices) | 21.6 | 24 | 26.4 | V |
Output Voltage (±12 V) | ±11.4 | ±12 | ±12.6 | V |
Output Current (at 100% load) | 83 | mA | ||
Output Power | 0.97 | W | ||
Isolation Voltage (1-second test) | 1500 | Vrms | ||
Operating Temperature | -40 | 85 | °C | |
Switching Frequency | 400 kHz |
Key Features
- 1.5-kV isolation (operational) with a 1-second test and continuous working voltage across the isolation barrier of 60 VDC or 42.5 VAC
- UL1950 recognized component and EN55022 class B EMC performance
- Available in 7-pin PDIP and 7-pin SOP packages
- Input voltages of 5 V, 15 V, or 24 V and output voltages of ±5 V, ±12 V, or ±15 V
- Device-to-device synchronization and thermal protection
- Short-circuit protection and high efficiency up to 86%
- On-chip device protection including output disable and synchronization of switching frequencies
Applications
- Signal path isolation
- Ground loop elimination
- Data acquisition
- Industrial control and instrumentation
- Test equipment
Q & A
- What is the maximum isolation voltage of the DCV010512DP-U/700?
The maximum isolation voltage is 1500 Vrms for a 1-second test.
- What are the available input voltages for this DC/DC converter?
The input voltages are 5 V, 15 V, or 24 V.
- What are the typical output voltages for this model?
The typical output voltages are ±5 V, ±12 V, or ±15 V.
- What is the switching frequency of the DCV010512DP-U/700?
The switching frequency is 400 kHz, derived from an 800-kHz oscillator.
- Does the DCV010512DP-U/700 have thermal protection?
- Can multiple DCV01 devices be synchronized?
- What is the maximum output power of the DCV010512DP-U/700?
The maximum output power is 1 W.
- Is the DCV010512DP-U/700 suitable for safety isolation circuits?
No, it is specified for operational isolation only and not intended for safety isolation circuits requiring reinforced isolation.
- What are the package options for the DCV010512DP-U/700?
The device is available in 7-pin PDIP and 7-pin SOP packages.
- What is the operating temperature range of the DCV010512DP-U/700?
The operating temperature range is -40°C to 85°C.