Overview
The BTA26-600BWRG is a high-performance Triac (Triode for Alternating Current) produced by STMicroelectronics. This component is part of the BTA26 series, designed for general-purpose AC switching applications. It is available in a TOP3 insulated package, which offers high current handling and low thermal resistance. The BTA26-600BWRG is UL recognized and complies with RoHS (2002/95/EC) standards, ensuring environmental sustainability.
Key Specifications
Parameter | Value | Unit |
---|---|---|
RMS On-State Current (IT(RMS)) | 25 | A |
Non-Repetitive Surge Peak On-State Current (ITSM) | 260 (60 Hz), 250 (50 Hz) | A |
Gate Trigger Current (IGT) - Snubberless | 50 mA | mA |
Gate Trigger Voltage (VGT) | 1.3 | V |
Holding Current (IH) | 50 mA | mA |
On-State Voltage (VTM) | 1.55 | V |
Off-State Leakage Current (IDRM) | 5 µA | µA |
Maximum Junction Temperature (Tj) | 125 °C | °C |
Insulation RMS Voltage | 2500 V | V |
Package Type | TOP3 Insulated |
Key Features
- High current handling up to 25 A RMS.
- Low thermal resistance with clip bonding.
- Standard commutation (4 quadrants) or snubberless (3 quadrants) operation.
- High turn-off commutation capability.
- UL recognized components (UL 1557, file ref: 81734).
- RoHS (2002/95/EC) compliant packages.
- Insulated tab rated at 2500 VRMS.
- Low on-state voltage (VTM) of 1.55 V.
- Low holding current (IH) of 50 mA.
Applications
- On/off functions in static relays.
- Heating regulation circuits.
- Induction motor starting circuits.
- Phase control operations in light dimmers.
- Motor speed controllers.
Q & A
- What is the maximum RMS on-state current of the BTA26-600BWRG?
The maximum RMS on-state current is 25 A.
- What is the gate trigger current for the snubberless operation of the BTA26-600BWRG?
The gate trigger current for snubberless operation is 50 mA.
- What is the maximum junction temperature for the BTA26-600BWRG?
The maximum junction temperature is 125 °C.
- Is the BTA26-600BWRG RoHS compliant?
- What is the insulation RMS voltage rating of the BTA26-600BWRG?
The insulation RMS voltage rating is 2500 V.
- What are the typical applications of the BTA26-600BWRG?
Typical applications include on/off functions in static relays, heating regulation circuits, induction motor starting circuits, phase control operations in light dimmers, and motor speed controllers.
- What is the package type of the BTA26-600BWRG?
The package type is TOP3 Insulated.
- What is the off-state leakage current of the BTA26-600BWRG?
The off-state leakage current (IDRM) is 5 µA.
- What is the holding current of the BTA26-600BWRG?
The holding current (IH) is 50 mA.
- Is the BTA26-600BWRG UL recognized?