Overview
The MC100EP11DG is a 3.3 V / 5 V ECL (Emitter-Coupled Logic) 1:2 differential fanout buffer produced by onsemi. This device is pin and functionally equivalent to the LVEL11 device but offers significantly faster AC performance. It is part of the 100 Series, which includes temperature compensation, making it ideal for applications requiring high-speed signal processing.
Key Specifications
Parameter | Condition | Value | Unit |
---|---|---|---|
Propagation Delay | Typical | 220 ps | ps |
Maximum Clock Frequency | Typical | > 3 GHz | GHz |
PECL Mode Operating Range | VCC = 3.0 V to 5.5 V with VEE = 0 V | ||
NECL Mode Operating Range | VCC = 0 V with VEE = −3.0 V to −5.5 V | ||
Power Supply (PECL Mode) | VEE = 0 V | 6 V | V |
Power Supply (NECL Mode) | VCC = 0 V | −6 V | V |
Operating Temperature Range | −40 to +85 °C | °C | |
Storage Temperature Range | −65 to +150 °C | °C | |
Output Current (Continuous) | 50 mA | mA | |
Output Current (Surge) | 100 mA | mA |
Key Features
- 220 ps typical propagation delay, making it suitable for high-speed applications.
- Maximum clock frequency greater than 3 GHz typical.
- Operates in both PECL and NECL modes with specified voltage ranges.
- Open input default state and safety clamp on inputs.
- Q outputs default LOW with inputs open or at VEE.
- Pb-Free, Halogen Free, and RoHS Compliant.
- Internal input pulldown resistor of 75 kΩ and ESD protection.
Applications
The MC100EP11DG is ideal for applications requiring high-speed signal processing and fanout, such as:
- Telecommunication systems.
- High-speed data transmission systems.
- Networking equipment.
- Test and measurement equipment.
- Other high-frequency digital systems.
Q & A
- What is the typical propagation delay of the MC100EP11DG?
The typical propagation delay is 220 ps.
- What is the maximum clock frequency of the MC100EP11DG?
The maximum clock frequency is greater than 3 GHz typical.
- In which modes can the MC100EP11DG operate?
The device operates in both PECL and NECL modes.
- What are the operating voltage ranges for PECL and NECL modes?
For PECL mode: VCC = 3.0 V to 5.5 V with VEE = 0 V. For NECL mode: VCC = 0 V with VEE = −3.0 V to −5.5 V.
- What happens to the Q outputs when the inputs are open or at VEE?
The Q outputs will default LOW.
- Is the MC100EP11DG RoHS compliant?
- What is the internal input pulldown resistor value?
The internal input pulldown resistor is 75 kΩ.
- What is the ESD protection level of the MC100EP11DG?
The device has ESD protection levels of > 4 kV (Human Body Model), > 200 V (Machine Model), and > 2 kV (Charged Device Model).
- What are the operating and storage temperature ranges?
The operating temperature range is −40 to +85 °C, and the storage temperature range is −65 to +150 °C.
- What are the typical output current limits?
The continuous output current is 50 mA, and the surge output current is 100 mA.