Overview
The TJA1040T/N1,118, produced by NXP USA Inc., is a high-speed CAN (Controller Area Network) transceiver designed to interface between the CAN protocol controller and the physical bus. It is primarily intended for high-speed applications, up to 1 MBaud, particularly in passenger cars. This device is known for its low current consumption and remote wake-up capability, making it an excellent choice for nodes that can be in power-down or standby mode in partially powered networks.
Key Specifications
Parameter | Conditions | Min. | Typ. | Max. | Unit |
---|---|---|---|---|---|
Supply Voltage (VCC) | No time limit | -0.3 | 6 | V | |
Operating Range (VCC) | 4.75 | 5.25 | V | ||
Supply Current (ICC) - Standby Mode | 5 | 10 | 15 | µA | |
Supply Current (ICC) - Normal Mode (Recessive) | VTXD = VCC/2 | 2.5 | 5 | 10 | mA |
Supply Current (ICC) - Normal Mode (Dominant) | 5 | 10 | mA | ||
Differential Bus Output Voltage (VCANH - VCANL) | VTXD = 0 V; Dominant; 45Ω < RL < 65Ω | 1.5 | 3.0 | V | |
Recessive Output Voltage | Normal Mode; VTXD = VCC; No Load | 0.5 VCC | 0.5 VCC | V | |
Operating Temperature | -40 | 150 | °C | ||
Package Type | 8-SOIC (0.154", 3.90mm Width) |
Key Features
- Fully compatible with the ISO 11898 standard.
- High-speed operation up to 1 MBaud.
- Very low-current standby mode with remote wake-up capability via the bus.
- Low ElectroMagnetic Emission (EME) and high ElectroMagnetic Immunity (EMI).
- Differential receiver with high common-mode range.
- Transceiver disengages from the bus in an unpowered state (zero load).
- Input levels compatible with 3.3 V and 5 V devices.
- Voltage source for stabilizing the recessive bus level if split termination is used.
- At least 110 nodes can be connected.
- Transmit Data (TXD) dominant time-out function.
- Bus pins protected against transients.
Applications
The TJA1040T/N1,118 is primarily used in high-speed CAN applications, particularly in the automotive sector for passenger cars. It is suitable for nodes that can be in power-down or standby mode in partially powered networks, making it an excellent choice for various automotive systems that require low power consumption and high reliability.
Q & A
- What is the primary function of the TJA1040T/N1,118?
The TJA1040T/N1,118 is a high-speed CAN transceiver that interfaces between the CAN protocol controller and the physical bus. - What is the maximum data rate supported by the TJA1040T/N1,118?
The TJA1040T/N1,118 supports data rates up to 1 MBaud. - What are the key features of the TJA1040T/N1,118's standby mode?
The standby mode features very low current consumption and remote wake-up capability via the bus. - Is the TJA1040T/N1,118 compatible with the ISO 11898 standard?
Yes, the TJA1040T/N1,118 is fully compatible with the ISO 11898 standard. - What is the operating temperature range of the TJA1040T/N1,118?
The operating temperature range is from -40°C to 150°C. - How many nodes can be connected using the TJA1040T/N1,118?
At least 110 nodes can be connected. - What type of package does the TJA1040T/N1,118 come in?
The TJA1040T/N1,118 comes in an 8-SOIC package. - Is the TJA1040T/N1,118 RoHS compliant?
Yes, the TJA1040T/N1,118 is RoHS compliant. - What is the purpose of the transmit data (TXD) dominant time-out function?
The TXD dominant time-out function prevents the bus from being permanently driven to a dominant state. - How does the TJA1040T/N1,118 protect against transients?
The bus pins are protected against transients.