Overview
The ADR392AUJZ-REEL7 is a precision voltage reference from Analog Devices Inc., part of the ADR39x family. This component is designed to provide a stable output voltage of 4.096 V with high precision and low power consumption. It features a compact 5-lead TSOT package and utilizes patented temperature drift curvature correction techniques to achieve a low temperature coefficient of 9 ppm/°C for the B grade and 25 ppm/°C for the A grade. This makes it ideal for battery-operated applications due to its low power operation, small size, and ease of use.
Key Specifications
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Output Voltage | VO | VIN = 4.3 V to 15 V, TA = 25°C | 4.090 | 4.096 | 4.102 | V |
Initial Accuracy | VOERR | VIN = 4.3 V to 15 V, TA = 25°C | 5 mV (B grade), 6 mV (A grade) | mV | ||
Temperature Coefficient | TCVO | −40°C < TA < +125°C | 9 ppm/°C (B grade), 25 ppm/°C (A grade) | ppm/°C | ||
Supply Voltage Headroom | VIN − VO | 300 mV | mV | |||
Line Regulation | ΔVO/ΔVIN | VIN = 4.3 V to 15 V, −40°C < TA < +125°C | 10 ppm/V | 25 ppm/V | ppm/V | |
Load Regulation | ΔVO/ΔILOAD | ILOAD = 0 mA to 5 mA, −40°C < TA < +125°C | 60 ppm/mA | ppm/mA | ||
Operating Temperature Range | TA | −40°C | +125°C | °C | ||
Supply Current | VIN = 4.3 V to 15 V, TA = 25°C | 140 μA | μA |
Key Features
- Precision output voltage of 4.096 V with high accuracy (±5 mV for B grade, ±6 mV for A grade)
- Low temperature coefficient: 9 ppm/°C for B grade and 25 ppm/°C for A grade
- Low power operation with a maximum supply current of 140 μA
- Compact 5-lead TSOT package
- No external capacitor required due to advanced design
- Low dropout voltage: 300 mV above the output voltage
- Wide operating temperature range: −40°C to +125°C
- Shutdown feature with a maximum current of 3 μA in shutdown mode
Applications
- Battery-powered instrumentation
- Portable medical instrumentation
- Data acquisition systems
- Industrial process controls
- Automotive applications
Q & A
- What is the output voltage of the ADR392AUJZ-REEL7? The output voltage is 4.096 V.
- What is the temperature coefficient of the ADR392AUJZ-REEL7? The temperature coefficient is 9 ppm/°C for the B grade and 25 ppm/°C for the A grade.
- What is the minimum supply voltage headroom required for the ADR392AUJZ-REEL7? The minimum supply voltage headroom is 300 mV above the output voltage.
- Does the ADR392AUJZ-REEL7 require external capacitors? No, it does not require external capacitors due to its advanced design.
- What is the operating temperature range of the ADR392AUJZ-REEL7? The operating temperature range is −40°C to +125°C.
- What is the maximum supply current of the ADR392AUJZ-REEL7? The maximum supply current is 140 μA.
- Does the ADR392AUJZ-REEL7 have a shutdown feature? Yes, it has a shutdown feature with a maximum current of 3 μA in shutdown mode.
- What are some common applications of the ADR392AUJZ-REEL7? Common applications include battery-powered instrumentation, portable medical instrumentation, data acquisition systems, industrial process controls, and automotive applications.
- What package type is the ADR392AUJZ-REEL7 available in? It is available in a 5-lead TSOT package.
- What is the maximum output current of the ADR392AUJZ-REEL7? The maximum output current is 5 mA.