Overview
The AD7193BRUZ-REEL, produced by Analog Devices Inc., is a highly advanced, low noise, 24-bit sigma-delta (Σ-Δ) analog-to-digital converter (ADC) designed for high precision measurement applications. It serves as a complete analog front end, incorporating a low noise gain stage that allows signals of small amplitude to interface directly with the ADC. This device is particularly useful in scenarios where high accuracy and low noise are critical.
Key Specifications
Parameter | Min | Typ | Max | Unit | Test Conditions/Comments |
---|---|---|---|---|---|
ADC Output Data Rate | 4.7 | - | 4800 | Hz | Chop disabled |
Power Supply | 3 | - | 5.25 | V | AVDD and DVDD |
Current Consumption | - | 4.65 | - | mA | - |
Package | - | - | - | - | 28-Lead TSSOP, 32-Lead LFCSP |
Operating Temperature | -40 | - | 105 | °C | - |
Resolution | - | - | - | - | 24 Bits |
Key Features
- Low Noise Performance: The AD7193 features a low noise, 24-bit sigma-delta ADC, making it suitable for high precision measurement applications.
- Flexible Input Configuration: The device can be configured to have four differential inputs or eight pseudo differential inputs.
- On-Chip Channel Sequencer: Allows several channels to be enabled simultaneously, with the AD7193 sequentially converting on each enabled channel.
- Flexible Digital Filter: Includes a fast settling option and a zero latency option, with variables such as output data rate and settling time dependent on the selected option.
- Internal or External Clock Source: The on-chip 4.92 MHz clock can be used, or an external clock or crystal can be employed.
- Power Efficiency: Operates with a power supply from 3 V to 5.25 V and consumes a current of 4.65 mA.
Applications
- PLC/DCS Analog Input Modules: Suitable for use in programmable logic controllers and distributed control systems.
- Data Acquisition: Ideal for high precision data acquisition systems.
- Strain Gage Transducers: Used in applications involving strain gage measurements.
- Pressure Measurement: Applicable in pressure measurement systems.
- Temperature Measurement: Used in temperature measurement applications.
- Flow Measurement: Suitable for flow measurement systems.
- Weigh Scales: Used in precision weighing applications.
- Chromatography: Applied in chromatography systems.
- Medical and Scientific Instrumentation: Used in various medical and scientific instruments requiring high precision measurements.
Q & A
- What is the resolution of the AD7193 ADC?
The AD7193 has a resolution of 24 bits.
- What are the power supply requirements for the AD7193?
The AD7193 operates with a power supply from 3 V to 5.25 V.
- What is the current consumption of the AD7193?
The AD7193 consumes a current of 4.65 mA.
- What are the available package options for the AD7193?
The AD7193 is available in 28-Lead TSSOP and 32-Lead LFCSP packages.
- Can the AD7193 use an external clock source?
Yes, the AD7193 can use either the on-chip 4.92 MHz clock or an external clock or crystal.
- What is the output data rate range of the AD7193?
The output data rate can be varied from 4.7 Hz to 4.8 kHz.
- Does the AD7193 support differential and pseudo differential inputs?
Yes, the AD7193 can be configured to have four differential inputs or eight pseudo differential inputs.
- What is the operating temperature range of the AD7193?
The operating temperature range is from -40°C to +105°C.
- Is the AD7193 suitable for medical and scientific instrumentation?
Yes, the AD7193 is suitable for various medical and scientific instruments requiring high precision measurements.
- Does the AD7193 have a built-in channel sequencer?
Yes, the AD7193 includes an on-chip channel sequencer that allows several channels to be enabled simultaneously.