Overview
The XTR300AIRGWR is a comprehensive industrial analog current/voltage output driver produced by Texas Instruments. This component is designed for industrial and process control applications, offering the flexibility to configure the output as either current or voltage via a digital I/V select pin. It does not require an external shunt resistor, needing only external gain-setting resistors and a loop compensation capacitor for operation. The XTR300 features separate driver and receiver channels, enhancing its versatility and functionality. It includes an Instrumentation Amplifier (IA) that can be used for remote voltage sensing or high-voltage, high-impedance measurements. The device is specified over an industrial temperature range of −40°C to +85°C and supports supply voltages up to 40V.
Key Specifications
Parameter | Conditions | Min | Max | Unit | |
---|---|---|---|---|---|
Supply Voltage | ±5 | ±20 | ±22 | V | |
Output Voltage Range | VS = ±20V | ±10 | ±17.5 | V | |
Output Current Range | VS = ±20V | ±20mA | ±24mA | mA | |
Offset Voltage (Voltage Output Mode) | TA = +25°C, VS = ±20V | ±0.4 | ±1.9 | mV | |
Offset Voltage (Current Output Mode) | TA = +25°C, VS = ±20V | ±0.4 | ±1.8 | mV | |
Temperature Range | −40 | +85 | °C | ||
Quiescent Current | IDRV = IAOUT = 0A | 1.8 | 2.3 | mA |
Key Features
- USER-SELECTABLE: Voltage or Current Output
- +40V Supply Voltage
- VOUT: ±10V (up to ±17.5V at ±20V supply)
- IOUT: ±20mA (linear up to ±24mA)
- SHORT- OR OPEN-CIRCUIT FAULT INDICATOR PIN
- NO CURRENT SHUNT REQUIRED
- OUTPUT DISABLE FOR SINGLE INPUT MODE
- THERMAL PROTECTION
- OVERCURRENT PROTECTION
- SEPARATE DRIVER AND RECEIVER CHANNELS
- DESIGNED FOR TESTABILITY
Applications
- PLC OUTPUT PROGRAMMABLE DRIVER
- INDUSTRIAL CROSS-CONNECTORS
- INDUSTRIAL HIGH-VOLTAGE I/O
- 3-WIRE-SENSOR CURRENT OR VOLTAGE OUTPUT
- ±10V 2- AND 4-WIRE VOLTAGE OUTPUT
Q & A
- What is the XTR300AIRGWR used for?
The XTR300AIRGWR is used as an industrial analog current/voltage output driver for industrial and process control applications.
- How can the output of the XTR300AIRGWR be configured?
The output can be configured as either current or voltage using the digital I/V select pin.
- What is the supply voltage range for the XTR300AIRGWR?
The supply voltage range is ±5V to ±22V.
- What are the output voltage and current ranges of the XTR300AIRGWR?
The output voltage range is ±10V (up to ±17.5V at ±20V supply), and the output current range is ±20mA (linear up to ±24mA).
- Does the XTR300AIRGWR require an external shunt resistor?
No, it does not require an external shunt resistor.
- What kind of protection does the XTR300AIRGWR offer?
The device offers thermal protection, overcurrent protection, and fault indicators for short or open circuits.
- What are the key applications of the XTR300AIRGWR?
Key applications include PLC output programmable drivers, industrial cross-connectors, industrial high-voltage I/O, and 3-wire sensor current or voltage output.
- What is the temperature range for the XTR300AIRGWR?
The specified temperature range is −40°C to +85°C.
- Does the XTR300AIRGWR have separate driver and receiver channels?
Yes, it has separate driver and receiver channels, which provide flexibility in its operation.
- How does the XTR300AIRGWR facilitate remote configuration and troubleshooting?
The device facilitates remote configuration and troubleshooting through its digital output selection capability, error flags, and monitor pins.