Overview
The TLA2021IRUGT, produced by Texas Instruments, is a 12-bit, single-channel delta-sigma analog-to-digital converter (ADC) designed for low-cost system-monitoring applications. This device is part of the TLA202x family, which includes the TLA2021, TLA2022, and TLA2024. The TLA2021 is notable for its ultra-small X2QFN package, measuring 2 mm × 1.5 mm, making it ideal for space-constrained designs. It integrates a voltage reference, oscillator, and an I2C-compatible interface, supporting both standard-mode and fast-mode operations. The device is suitable for various monitoring tasks such as supply or battery voltage supervision, current sensing, and temperature measurements.
Key Specifications
Parameter | Value | Unit |
---|---|---|
Resolution | 12-bit | |
Number of Channels | 1 | |
Input Type | Single-ended or differential | |
Full-Scale Range (FSR) | ±2.048 V | V |
Supply Voltage Range | 2 V to 5.5 V | V |
Operating Temperature Range | –40°C to +85°C | °C |
Data Rate | 128 SPS to 3.3 kSPS | SPS |
Current Consumption | 150 µA | µA |
Package Type | X2QFN (RUG) with 10 pins | |
I2C Interface | Supports standard-mode and fast-mode, three pin-selectable I2C addresses |
Key Features
- Industry’s lowest-cost 12-bit delta-sigma ADCs
- Ultra-small X2QFN package: 2 mm × 1.5 mm
- Highly integrated with voltage reference and oscillator
- Low current consumption: 150 µA
- Wide supply range: 2 V to 5.5 V
- Programmable data rate: 128 SPS to 3.3 kSPS
- I2C-compatible interface supporting standard-mode and fast-mode, with three pin-selectable I2C addresses
- Operating temperature range: –40°C to +85°C
Applications
The TLA2021IRUGT is designed for various system-monitoring applications, including:
- Supply or battery voltage supervision
- Current sensing
- Temperature measurements
- General-purpose data acquisition in power- and space-constrained systems
Q & A
- What is the resolution of the TLA2021IRUGT?
The TLA2021IRUGT has a 12-bit resolution.
- What types of inputs can the TLA2021IRUGT handle?
The TLA2021IRUGT can handle either single-ended or differential inputs.
- What is the full-scale range (FSR) of the TLA2021IRUGT?
The full-scale range (FSR) of the TLA2021IRUGT is fixed at ±2.048 V.
- What is the supply voltage range for the TLA2021IRUGT?
The supply voltage range for the TLA2021IRUGT is from 2 V to 5.5 V.
- What is the operating temperature range of the TLA2021IRUGT?
The operating temperature range of the TLA2021IRUGT is from –40°C to +85°C.
- What are the data rate options for the TLA2021IRUGT?
The data rate for the TLA2021IRUGT can be programmed from 128 SPS to 3.3 kSPS.
- How much current does the TLA2021IRUGT consume?
The TLA2021IRUGT consumes 150 µA of current.
- What type of package does the TLA2021IRUGT come in?
The TLA2021IRUGT comes in an ultra-small X2QFN (RUG) package with 10 pins.
- Does the TLA2021IRUGT support I2C communication?
Yes, the TLA2021IRUGT supports I2C communication in both standard-mode and fast-mode, with three pin-selectable I2C addresses.
- What are some common applications for the TLA2021IRUGT?
The TLA2021IRUGT is commonly used for supply or battery voltage supervision, current sensing, temperature measurements, and general-purpose data acquisition in power- and space-constrained systems.