Overview
The OPA2335AIDGKRG4 is a dual, single-supply CMOS operational amplifier from Texas Instruments, part of the OPA334 and OPA335 series. These amplifiers utilize auto-zeroing techniques to provide very low offset voltage and near-zero drift over time and temperature. This makes them highly suitable for applications requiring high precision and stability.
Key Specifications
Parameter | Condition | Min | Typ | Max | Units |
---|---|---|---|---|---|
Input Offset Voltage (VOS) | VCM = VS/2 | 1 | - | 5 | µV |
Offset Voltage Drift (dVOS/dT) | - | ±0.02 | - | ±0.05 | µV/°C |
Input Bias Current (IB) | VCM = VS/2 | - | ±70 | ±200 | pA |
Quiescent Current (IQ) | IO = 0 | - | 285 | 350 | µA |
Operating Voltage Range | - | 2.7 | - | 5.5 | V |
Operating Temperature Range | - | -40 | - | 125 | °C |
Storage Temperature Range | - | -65 | - | 150 | °C |
Shutdown Time (tOFF) | - | - | 1 | - | µs |
Shutdown Voltage (VL, VH) | - | 0, 0.8 | - | - | V |
Key Features
- Low Offset Voltage: 5µV (max)
- Zero Drift: 0.05µV/°C (max)
- Quiescent Current: 285µA
- Single-Supply Operation: 2.7V to 5.5V
- Single and Dual Versions: Available in both single and dual amplifier configurations
- Shutdown Capability: Fast shutdown time of 1µs
- MicroSIZE Packages: Available in SOT23-5, SOT23-6, MSOP-8, and SO-8 packages
Applications
- Transducer Applications: Suitable for use with various transducers due to its high precision and stability.
- Temperature Measurement: Ideal for temperature measurement applications requiring low drift.
- Electronic Scales: Used in electronic scales for accurate weight measurements.
- Medical Instrumentation: Applied in medical devices where precision and low noise are critical.
- Battery-Powered Instruments: Suitable for battery-powered devices due to its low quiescent current.
- Handheld Test Equipment: Used in handheld test equipment for its compact size and low power consumption.
Q & A
- What is the maximum input offset voltage of the OPA2335AIDGKRG4?
The maximum input offset voltage is 5µV.
- What is the drift of the input offset voltage over temperature?
The drift is 0.05µV/°C (max).
- What is the quiescent current of the OPA2335AIDGKRG4?
The quiescent current is 285µA.
- What is the operating voltage range of the OPA2335AIDGKRG4?
The operating voltage range is from 2.7V to 5.5V.
- What are the available package types for the OPA2335AIDGKRG4?
Available in SOT23-5, SOT23-6, MSOP-8, and SO-8 packages.
- Does the OPA2335AIDGKRG4 have a shutdown feature?
Yes, it has a shutdown feature with a fast shutdown time of 1µs.
- What are some typical applications of the OPA2335AIDGKRG4?
Typical applications include transducer applications, temperature measurement, electronic scales, medical instrumentation, battery-powered instruments, and handheld test equipment.
- What is the operating temperature range of the OPA2335AIDGKRG4?
The operating temperature range is from -40°C to 125°C.
- Is the OPA2335AIDGKRG4 RoHS compliant?
Yes, it is RoHS compliant.
- How many amplifiers are in the OPA2335AIDGKRG4 package?
The package contains two amplifiers.