The Texas Instruments ADS1299-6PAGR is a low-noise, 6-channel, 24-bit analog-to-digital converter (ADC) optimized for biopotential measurements. It is part of the ADS1299 family, which includes four-, six-, and eight-channel variants. This device is designed to provide high accuracy and low noise levels, making it ideal for applications such as electrocardiography (ECG), electromyography (EMG), and electrophysiology. The ADS1299-6PAGR integrates all commonly required features for extracranial electroencephalogram (EEG) and ECG applications, enabling the creation of scalable medical instrumentation systems with reduced size, power, and overall cost.
Key Specifications
Parameter | Value |
---|---|
Number of Channels | 6 |
Resolution (Bits) | 24 |
Input-Referred Noise | 1 µV PP (70-Hz BW) |
Input Bias Current | 300 pA |
Data Rate | 250 SPS to 16 kSPS |
CMRR | –110 dB |
Programmable Gain | 1, 2, 4, 6, 8, 12, or 24 |
Analog Supply Voltage | 4.75 V to 5.25 V |
Digital Supply Voltage | 1.8 V to 3.6 V |
Package Type | TQFP-64 (10x10 mm) |
Operating Temperature Range | –40°C to +85°C |
Interface Type | SPI-Compatible Serial Interface |
Power Consumption | 15 mW (typical) |
Key Features
- Up to eight low-noise programmable gain amplifiers (PGAs) and eight high-resolution simultaneous-sampling ADCs.
- Built-in bias drive amplifier, lead-off detection, and test signals.
- Built-in oscillator and internal or external reference options.
- Flexible power-down and standby mode.
- Pin-compatible with the ADS129x family.
- SPI-compatible serial interface.
- Optional SRB pins for referential montage configuration.
- Low power consumption of 15 mW (typical).
Applications
- Electrocardiography (ECG): High accuracy and low noise levels make it suitable for ECG measurements.
- Electromyography (EMG): Ideal for EMG signal measurements with high accuracy and low noise levels.
- Electrophysiology: Suitable for measuring electrophysiological signals such as EEG, ECG, and EMG.
- Medical Instrumentation: Includes applications like EEG studies, fetal ECG, sleep study monitors, Bispectral Index (BIS), and Evoked Audio Potential (EAP).
Q & A
- Q: What is the input-referred noise of the ADS1299-6PAGR?
A: The input-referred noise is 1 µV PP with a bandwidth of 70 Hz. - Q: Can the ADS1299-6PAGR be used for ECG measurements?
A: Yes, it can be used for ECG measurements due to its high accuracy and low noise levels. - Q: What is the power consumption of the ADS1299-6PAGR?
A: The power consumption is 15 mW (typical). - Q: Can the ADS1299-6PAGR be used for EMG measurements?
A: Yes, it can be used for EMG measurements due to its high accuracy and low noise levels. - Q: What is the data rate range of the ADS1299-6PAGR?
A: The data rate range is from 250 SPS to 16 kSPS. - Q: What is the common-mode rejection ratio (CMRR) of the ADS1299-6PAGR?
A: The CMRR is –110 dB. - Q: What are the programmable gain options for the ADS1299-6PAGR?
A: The programmable gain options are 1, 2, 4, 6, 8, 12, or 24. - Q: Does the ADS1299-6PAGR have built-in lead-off detection?
A: Yes, it has built-in lead-off detection using an excitation current sink or source. - Q: Can multiple ADS1299-6PAGR devices be cascaded?
A: Yes, multiple devices can be cascaded in a daisy-chain configuration for high channel count systems. - Q: What is the operating temperature range of the ADS1299-6PAGR?
A: The operating temperature range is –40°C to +85°C.