Overview
The ADC12081CIVT is a 12-bit, 5 MSPS (Mega Samples Per Second) self-calibrating, pipelined analog-to-digital converter (ADC) produced by National Semiconductor. This integrated circuit is designed to provide high-speed and high-accuracy analog-to-digital conversion, making it suitable for a variety of applications that require precise and rapid data acquisition.
Key Specifications
Parameter | Value |
---|---|
Resolution | 12 bits |
Sampling Rate | 5 MSPS |
Input Type | Single-ended |
Package Type | 32-LQFP (7x7) |
Power Supply | Single 3V or 5V supply |
Operating Temperature | -40°C to 85°C |
DNL (Differential Non-Linearity) | ±0.5 LSB |
INL (Integral Non-Linearity) | ±1 LSB |
Key Features
- Self-calibrating architecture for improved accuracy
- Pipelined architecture for high-speed conversion
- Low power consumption
- Single 3V or 5V power supply
- High linearity with ±0.5 LSB DNL and ±1 LSB INL
- Operating temperature range from -40°C to 85°C
Applications
The ADC12081CIVT is versatile and can be used in various applications, including:
- Medical imaging and diagnostic equipment
- Industrial automation and control systems
- Aerospace and defense systems
- High-speed data acquisition systems
- Telecommunications and networking equipment
Q & A
- What is the resolution of the ADC12081CIVT?
The ADC12081CIVT has a resolution of 12 bits. - What is the maximum sampling rate of the ADC12081CIVT?
The maximum sampling rate is 5 MSPS. - What type of input does the ADC12081CIVT support?
The ADC12081CIVT supports single-ended inputs. - What is the package type of the ADC12081CIVT?
The package type is 32-LQFP (7x7). - What is the power supply requirement for the ADC12081CIVT?
The ADC12081CIVT requires a single 3V or 5V power supply. - What is the operating temperature range of the ADC12081CIVT?
The operating temperature range is from -40°C to 85°C. - What are the DNL and INL specifications of the ADC12081CIVT?
The DNL is ±0.5 LSB, and the INL is ±1 LSB. - Is the ADC12081CIVT self-calibrating?
Yes, the ADC12081CIVT has a self-calibrating architecture. - What are some common applications of the ADC12081CIVT?
Common applications include medical imaging, industrial automation, aerospace and defense systems, high-speed data acquisition systems, and telecommunications equipment. - Where can I find detailed technical specifications for the ADC12081CIVT?
Detailed technical specifications can be found in the datasheet available on websites such as Digi-Key, Farnell, or the official National Semiconductor documentation.