Overview
The 6N137-560E is a single-channel logic output optocoupler manufactured by Broadcom Limited. This device is designed to provide high-speed data transfer and electrical isolation between the input and output circuits. It features an integrated optical coupler with a high-efficiency input LED and an open collector, Schottky clamped output stage. The 6N137-560E is widely used in various applications requiring reliable and fast data transmission with robust isolation.
Key Specifications
Parameter | Value | Unit |
---|---|---|
Number of Channels | 1 | - |
Input Type | DC | - |
Input Forward Voltage (Typ) | 1.5 | V |
Supply Voltage | 4.5V ~ 5.5V | V |
Output Type | Open Collector, Schottky Clamped | - |
Propagation Delay (Max) | 75ns / 75ns | ns |
Data Rate | 10MBd | - |
Isolation Voltage | 3750Vrms | V |
Operating Temperature | -40°C ~ 85°C | °C |
Package / Case | 8-DIP, 8-SMD (Gull Wing) | - |
Mounting Type | Through Hole, Surface Mount | - |
Current - Output / Channel | 50 mA | mA |
Current - DC Forward (Max) | 20 mA | mA |
RoHS Status | ROHS3 Compliant | - |
Key Features
- High-speed data transfer with a data rate of 10 MBd
- Open collector, Schottky clamped output stage for reliable operation
- High common mode transient immunity of 1 kV/µs
- Low input current capability of 5 mA
- Robust electrical isolation with 3750 Vrms
- Operating temperature range from -40°C to 85°C
- Compliant with various safety standards including UL1577, cUL, and CQC GB8898-2011
Applications
- Microprocessor system interface
- PLC and ATE input/output isolation
- Computer peripheral interface
- Digital fieldbus isolation (CC-link, DeviceNet, Profibus, SDS)
- High-speed A/D and D/A conversion
- AC plasma display panel level shifting
- Multiplexed data transmission
- Digital control power supply
- Ground loop elimination and noise isolation
Q & A
- What is the data rate of the 6N137-560E optocoupler?
The data rate of the 6N137-560E is 10 MBd.
- What is the typical propagation delay of the 6N137-560E?
The typical propagation delay is 75 ns for both high and low output levels.
- What is the isolation voltage of the 6N137-560E?
The isolation voltage is 3750 Vrms.
- What are the operating temperature ranges for the 6N137-560E?
The operating temperature range is from -40°C to 85°C.
- What are the package options for the 6N137-560E?
The package options include 8-DIP and 8-SMD (Gull Wing).
- Is the 6N137-560E RoHS compliant?
Yes, the 6N137-560E is ROHS3 compliant.
- What is the maximum output current per channel for the 6N137-560E?
The maximum output current per channel is 50 mA.
- What safety standards does the 6N137-560E comply with?
The 6N137-560E complies with standards such as UL1577, cUL, and CQC GB8898-2011.
- What is the common mode transient immunity of the 6N137-560E?
The common mode transient immunity is at least 1 kV/µs.
- What is the input forward voltage of the 6N137-560E?
The typical input forward voltage is 1.5 V.