Overview
The MAX1322ECM is a high-performance analog-to-digital converter (ADC) produced by Analog Devices Inc./Maxim Integrated. This device is part of the MAX1316–MAX1326 family and is known for its precision and versatility in various analog-to-digital conversion applications. It offers a range of input voltage options and advanced features such as overvoltage protection and simultaneous sampling, making it suitable for a wide array of industrial, medical, and automotive applications.
Key Specifications
Parameter | Value |
---|---|
Input Type | Single-Ended |
Architecture | SAR (Successive Approximation Register) |
SNR - Signal to Noise Ratio | 76 dB |
Minimum Operating Temperature | -40°C |
Voltage - Supply, Analog | 4.75V ~ 5.25V |
Voltage - Supply, Digital | 2.7V ~ 5.25V |
Reference Type | External, Internal |
Key Features
- Simultaneous sampling of multiple channels
- Overvoltage protection circuitry
- High signal-to-noise ratio (SNR) of 76 dB
- Wide operating temperature range from -40°C to 85°C
- Flexible supply voltage options for both analog and digital sections
- External and internal reference options
Applications
The MAX1322ECM is suitable for a variety of applications, including:
- Industrial automation and control systems
- Medical devices requiring high precision ADCs
- Automotive systems for sensor data acquisition
- Data acquisition systems in scientific and research environments
- High-precision measurement instruments
Q & A
- What is the input type of the MAX1322ECM? The input type is single-ended.
- What is the architecture of the MAX1322ECM? The architecture is SAR (Successive Approximation Register).
- What is the signal-to-noise ratio (SNR) of the MAX1322ECM? The SNR is 76 dB.
- What are the supply voltage ranges for the MAX1322ECM? The analog supply voltage range is 4.75V ~ 5.25V, and the digital supply voltage range is 2.7V ~ 5.25V.
- Does the MAX1322ECM have overvoltage protection? Yes, it includes overvoltage protection circuitry.
- What are the reference type options for the MAX1322ECM? The device supports both external and internal reference types.
- What is the minimum operating temperature of the MAX1322ECM? The minimum operating temperature is -40°C.
- In what types of applications is the MAX1322ECM commonly used? It is commonly used in industrial automation, medical devices, automotive systems, and high-precision measurement instruments.
- Does the MAX1322ECM support simultaneous sampling? Yes, it supports simultaneous sampling of multiple channels.
- Where can I find detailed specifications for the MAX1322ECM? Detailed specifications can be found on the official Analog Devices website, as well as on distributor websites like Digi-Key and Mouser.