Overview
The MAX1310ECM+T is a 12-bit, analog-to-digital converter (ADC) produced by Analog Devices Inc./Maxim Integrated. This component is part of the MAX1304–MAX1314 series, which offers high-performance simultaneous sampling for multiple independent input channels. The MAX1310 specifically provides two independent input channels with a ±5V input range and ±16.5V fault-tolerant inputs. It is designed for applications requiring precise and simultaneous data acquisition.
Key Specifications
Parameter | Value |
---|---|
Resolution | 12-bit |
Number of ADC Inputs | 2 |
Input Voltage Range | ±5V |
Fault-Tolerant Input Range | ±16.5V |
Conversion Time | 0.9µs (two channels), 1.98µs (up to eight channels) |
Throughput Rate | 456ksps per channel (8-channel mode) |
Track-and-Hold Input Bandwidth | 20MHz |
Reference Type | Internal (+2.5V) or External (+2.0V to +3.0V) |
Analog Supply Voltage | +4.75V to +5.25V |
Digital Supply Voltage | +2.7V to +5.25V |
Total Supply Current | 57mA |
Operating Temperature Range | -40°C to +85°C |
Package Type | 48-pin LQFP, 7mm x 7mm |
Key Features
- Simultaneous sampling of two independent input channels
- High-speed conversion: 0.9µs for two channels, 1.98µs for up to eight channels
- High throughput rate: 456ksps per channel in 8-channel mode
- 20MHz track-and-hold input bandwidth
- Internal or external reference options
- Power-saving modes
- Fault-tolerant inputs up to ±16.5V
- Extended operating temperature range: -40°C to +85°C
Applications
The MAX1310ECM+T is suitable for a variety of applications that require high-speed, simultaneous data acquisition. These include:
- Data acquisition systems
- Industrial control systems
- Medical devices requiring precise signal measurement
- Aerospace and defense systems
- Automotive systems needing robust and fault-tolerant ADCs
Q & A
- What is the resolution of the MAX1310ECM+T ADC?
The MAX1310ECM+T has a 12-bit resolution. - How many independent input channels does the MAX1310ECM+T have?
The MAX1310ECM+T has two independent input channels. - What is the input voltage range of the MAX1310ECM+T?
The input voltage range is ±5V. - What is the fault-tolerant input range of the MAX1310ECM+T?
The fault-tolerant input range is ±16.5V. - What is the conversion time for two channels?
The conversion time for two channels is 0.9µs. - What is the throughput rate per channel in 8-channel mode?
The throughput rate per channel in 8-channel mode is 456ksps. - What is the track-and-hold input bandwidth of the MAX1310ECM+T?
The track-and-hold input bandwidth is 20MHz. - What are the supply voltage ranges for the MAX1310ECM+T?
The analog supply voltage range is +4.75V to +5.25V, and the digital supply voltage range is +2.7V to +5.25V. - What is the total supply current of the MAX1310ECM+T when fully operational?
The total supply current is 57mA. - What is the operating temperature range of the MAX1310ECM+T?