Overview
The MAX110BEWE+T is an analog-to-digital converter (ADC) designed by Analog Devices Inc./Maxim Integrated, utilizing a sigma-delta architecture. This component is tailored for precise voltage measurements in various data acquisition applications. It features high resolution and accuracy, making it suitable for a range of monitoring and control systems.
Key Specifications
Parameter | Value |
---|---|
Number of Bits | 14 |
Sampling Rate (Per Second) | 50 |
Number of Inputs | 2 (Differential) |
Data Interface | SPI |
Voltage Supply, Analog | ±5V |
Voltage Supply, Digital | ±5V |
Operating Temperature | 0°C ~ 70°C (typical), -40°C ~ 85°C (extended range) |
Package / Case | 16-SOIC (0.295", 7.50mm Width) |
Power Dissipation | 762 mW |
Key Features
- High resolution of 14 bits, providing precise voltage measurements.
- Dual differential inputs for measuring two signals simultaneously, enhancing noise canceling and signal accuracy.
- Sigma-delta architecture ensures high accuracy and noise reduction.
- External reference voltage allows for customizable measurement range.
- SPI data interface for easy integration with microcontrollers and digital systems.
- Low sampling rate of 50 samples per second, optimized for slow-changing signals.
- Robust SOIC packaging ensures durability in various operating conditions.
Applications
- Industrial monitoring and control systems.
- Environmental monitoring.
- Medical equipment for patient monitoring.
- Laboratory and research data acquisition.
- Automation systems.
Q & A
- What is the resolution of the MAX110BEWE+T ADC?
The MAX110BEWE+T has a resolution of 14 bits. - How many differential inputs does the MAX110BEWE+T have?
The MAX110BEWE+T has 2 differential inputs. - What is the sampling rate of the MAX110BEWE+T?
The sampling rate is 50 samples per second. - What data interface does the MAX110BEWE+T use?
The MAX110BEWE+T uses an SPI data interface. - What are the voltage supply requirements for the MAX110BEWE+T?
The MAX110BEWE+T requires ±5V for both analog and digital supplies. - What is the operating temperature range of the MAX110BEWE+T?
The typical operating temperature range is 0°C ~ 70°C, with an extended range of -40°C ~ 85°C. - What type of packaging does the MAX110BEWE+T use?
The MAX110BEWE+T is packaged in a 16-SOIC (0.295", 7.50mm Width). - Is the MAX110BEWE+T still in production?
No, the MAX110BEWE+T is obsolete and no longer being manufactured. - What are some common applications of the MAX110BEWE+T?
Common applications include industrial monitoring, environmental monitoring, medical equipment, laboratory and research data acquisition, and automation systems. - What architecture does the MAX110BEWE+T use?
The MAX110BEWE+T uses a sigma-delta architecture.