Overview
The MAX1084BCSA+T is a 10-bit, single-supply, low-power analog-to-digital converter (ADC) designed by Analog Devices Inc./Maxim Integrated. This device is optimized for high-speed conversion and low power consumption, making it ideal for various applications requiring precise and efficient data acquisition.
Key Specifications
Specification | Value |
---|---|
Converter Resolution | 10 bits |
Sampling Rate | 400 ksps |
Operating Supply Voltage | 4.5 V to 5.5 V |
Integral Nonlinearity (INL) | ±1 LSB |
Package Type | 8-pin SO (Small Outline) |
Mounting Type | SMD (Surface Mount Device) |
Operating Temperature Range | 0°C to +70°C |
Storage Temperature Range | -60°C to +150°C |
Key Features
- Single-supply operation: +4.5V to +5.5V
- Internal +2.5V reference voltage
- Low power consumption: 2.5 mA at 400 ksps
- SPI/QSPI/MICROWIRE 3-wire serial interface
- Internal track/hold amplifier
- Pin-compatible with MAX1242/MAX1243 for higher-speed upgrades
Applications
- Portable data logging
- Data acquisition systems
- Medical instruments
- Battery-powered instruments
- Pen digitizers
- Process control systems
Q & A
- What is the resolution of the MAX1084BCSA+T ADC?
The MAX1084BCSA+T has a 10-bit resolution. - What is the sampling rate of the MAX1084BCSA+T?
The sampling rate is 400 ksps. - What is the operating supply voltage range for the MAX1084BCSA+T?
The operating supply voltage range is from 4.5 V to 5.5 V. - What type of serial interface does the MAX1084BCSA+T use?
The MAX1084BCSA+T uses a SPI/QSPI/MICROWIRE 3-wire serial interface. - Is the MAX1084BCSA+T suitable for low-power applications?
Yes, it is designed for low power consumption, typically 2.5 mA at 400 ksps. - What is the package type of the MAX1084BCSA+T?
The package type is an 8-pin SO (Small Outline). - What is the operating temperature range for the MAX1084BCSA+T?
The operating temperature range is from 0°C to +70°C. - Is the MAX1084BCSA+T pin-compatible with other ADCs?
Yes, it is pin-compatible with the MAX1242/MAX1243 for higher-speed upgrades. - What are some common applications of the MAX1084BCSA+T?
Common applications include portable data logging, data acquisition systems, medical instruments, battery-powered instruments, pen digitizers, and process control systems. - What is the storage temperature range for the MAX1084BCSA+T?
The storage temperature range is from -60°C to +150°C.