The LTC2122IUK#PBF is a high-performance, 14-bit analog-to-digital converter (ADC) produced by Analog Devices Inc. This device is designed for high-speed data acquisition and is particularly suited for applications requiring high accuracy and low power consumption. The LTC2122IUK#PBF operates at a sampling rate of up to 170 MSPS, making it ideal for various high-speed data conversion tasks.
Key Specifications
Specification | Value |
---|---|
Resolution | 14 bits |
Sampling Rate | Up to 170 MSPS |
Package Type | 48-lead QFN |
Lead Free Status / RoHS Status | Lead free / RoHS compliant |
Operating Temperature Range | -40°C to 85°C |
Power Consumption | Typically 1.1W at 170 MSPS |
Key Features
- High-speed sampling up to 170 MSPS
- 14-bit resolution with high accuracy
- Low power consumption, typically 1.1W at 170 MSPS
- 48-lead QFN package for compact design
- Lead free and RoHS compliant
- Wide operating temperature range from -40°C to 85°C
Applications
The LTC2122IUK#PBF is suitable for a variety of high-speed data acquisition applications, including:
- Medical imaging and diagnostics
- Radar and surveillance systems
- High-speed data acquisition systems
- Test and measurement equipment
- Wireless communication systems
Q & A
- What is the resolution of the LTC2122IUK#PBF ADC?
The LTC2122IUK#PBF has a resolution of 14 bits. - What is the maximum sampling rate of the LTC2122IUK#PBF?
The maximum sampling rate is up to 170 MSPS. - What is the package type of the LTC2122IUK#PBF?
The package type is a 48-lead QFN. - Is the LTC2122IUK#PBF lead free and RoHS compliant?
Yes, it is lead free and RoHS compliant. - What is the typical power consumption of the LTC2122IUK#PBF at 170 MSPS?
The typical power consumption is 1.1W at 170 MSPS. - What is the operating temperature range of the LTC2122IUK#PBF?
The operating temperature range is from -40°C to 85°C. - What are some common applications of the LTC2122IUK#PBF?
Common applications include medical imaging, radar and surveillance systems, high-speed data acquisition systems, test and measurement equipment, and wireless communication systems. - How does the LTC2122IUK#PBF contribute to high-speed data acquisition?
The LTC2122IUK#PBF contributes to high-speed data acquisition with its high sampling rate and high resolution, ensuring accurate and fast data conversion. - Is the LTC2122IUK#PBF suitable for medical imaging applications?
Yes, it is suitable for medical imaging applications due to its high accuracy and high-speed sampling capabilities. - Where can I find detailed specifications and datasheets for the LTC2122IUK#PBF?
Detailed specifications and datasheets can be found on the official Analog Devices website, as well as on distributor websites like Digi-Key and Mouser Electronics.