Overview
The ADXL1004BCPZ-RL, produced by Analog Devices Inc., is a low noise, single-axis, MEMS (Microelectromechanical Systems) accelerometer. It is designed to provide an analog output proportional to mechanical vibration, making it ideal for high bandwidth applications such as vibration analysis and predictive maintenance. The device features a high g range of ±500 g and a resonant frequency of 45 kHz, enabling the measurement of vibration patterns caused by small moving components like internal bearings. It operates over a wide temperature range of −40°C to +125°C and is available in a 32-lead LFCSP package measuring 5 mm × 5 mm × 1.80 mm.
Key Specifications
Parameter | Value | Unit |
---|---|---|
Full-scale Range | ±500 | g |
Linear Frequency Response Range | dc to 24 kHz (typical, 3 dB point) | |
Resonant Frequency | 45 kHz (typical) | |
Noise Density | 125 μg/√Hz (typical) | |
Supply Voltage | 3.3 V to 5.25 V | |
Current Consumption | 1.0 mA (typical), 225 µA (standby mode) | |
Operating Temperature Range | −40°C to +125°C | |
Package Type | 32-Lead LFCSP (5 mm × 5 mm × 1.80 mm) | |
Cross Axis Sensitivity | ±1.5% | |
Linearity | ±0.25% of full-scale range |
Key Features
- Single, in-plane axis accelerometer with analog output
- Ultralow noise density of 125 μg/√Hz across the linear frequency range
- Full electrostatic self-test (ST) and overrange (OR) indicator
- Low power consumption with typical current of 1.0 mA and standby mode current of 225 µA
- Single-supply operation with voltage range of 3.3 V to 5.25 V
- Output voltage ratiometric to supply
- High sensitivity stability over temperature within 5%
- Immune to external shocks up to 10,000 g
Applications
- Condition monitoring and predictive maintenance
- Asset health and vibration analysis systems
- Test and measurement
- Health usage monitoring systems (HUMSs)
- Acoustic emissions and bearing fault detection and diagnostics
- Heavy machine equipment and HVAC systems
Q & A
- What is the full-scale range of the ADXL1004?
The full-scale range of the ADXL1004 is ±500 g.
- What is the typical noise density of the ADXL1004?
The typical noise density of the ADXL1004 is 125 μg/√Hz.
- What is the operating temperature range of the ADXL1004?
The operating temperature range of the ADXL1004 is −40°C to +125°C.
- What is the package type and size of the ADXL1004?
The ADXL1004 is available in a 32-lead LFCSP package measuring 5 mm × 5 mm × 1.80 mm.
- What are the key applications of the ADXL1004?
The ADXL1004 is used in condition monitoring, predictive maintenance, asset health, test and measurement, and bearing fault detection among other applications.
- How does the ADXL1004 handle external shocks?
The ADXL1004 is immune to external shocks up to 10,000 g.
- What is the power consumption of the ADXL1004 in normal and standby modes?
The ADXL1004 consumes 1.0 mA (typical) in normal mode and 225 µA (typical) in standby mode.
- Does the ADXL1004 support self-testing?
Yes, the ADXL1004 supports full electrostatic self-test (ST) and an overrange (OR) indicator.
- What is the recommended ADC sample rate for the ADXL1004?
A minimum ADC sample rate of 200 kHz is recommended to avoid aliasing.
- Are there evaluation boards available for the ADXL1004?
Yes, the EVAL-ADXL1004Z evaluation boards are available for quickly evaluating the performance of the ADXL1004 vibration sensors.