Overview
The ADXL1004BCPZ, produced by Analog Devices Inc., is a low noise, single-axis, MEMS (Microelectromechanical Systems) accelerometer. This device is designed to provide an analog output proportional to mechanical vibration, making it highly suitable for vibration measurements in high bandwidth applications. The ADXL1004BCPZ features a high g range of ±500 g, ultralow noise density, and a wide linear frequency response range, making it ideal for applications such as condition monitoring, predictive maintenance, and asset health monitoring.
Key Specifications
Parameter | Value |
---|---|
Full-scale range | ±500 g |
Linear frequency response range | dc to 24 kHz (typical, 3 dB point) |
Resonant frequency | 45 kHz (typical) |
Noise density | 125 μg/√Hz |
Sensitivity | 4 mV/g |
Supply voltage | 3.3 V to 5.25 V |
Power consumption | 1.0 mA (typical at 5.0 V) |
Operating temperature range | −40°C to +125°C |
Package | 32-lead LFCSP (5 mm × 5 mm × 1.80 mm with exposed pad) |
Pin count | 32 |
RoHS status | RoHS compliant |
Key Features
- Single, in-plane axis accelerometer with analog output
- Ultralow noise density over an extended frequency range
- Full electrostatic self-test and overrange indicator
- High g range of ±500 g, suitable for high vibration environments
- Linear frequency response range: dc to 24 kHz (typical, 3 dB point)
- Resonant frequency: 45 kHz (typical)
- Low power consumption with standby mode for power saving
- Single-supply operation with output voltage ratiometric to supply
- Immune to external shocks up to 10,000 g
Applications
- Condition monitoring
- Predictive maintenance
- Asset health monitoring
- Test and measurement
- Health usage monitoring systems (HUMSs)
- Acoustic emissions
- Bearing fault detection and diagnostics
- Vibration analysis systems for monitoring machine or system health
Q & A
- What is the full-scale range of the ADXL1004BCPZ?
The full-scale range of the ADXL1004BCPZ is ±500 g. - What is the typical noise density of the ADXL1004BCPZ?
The typical noise density is 125 μg/√Hz. - What is the linear frequency response range of the ADXL1004BCPZ?
The linear frequency response range is dc to 24 kHz (typical, 3 dB point). - What is the resonant frequency of the ADXL1004BCPZ?
The resonant frequency is 45 kHz (typical). - What is the supply voltage range for the ADXL1004BCPZ?
The supply voltage range is 3.3 V to 5.25 V. - How much power does the ADXL1004BCPZ consume in measurement mode?
The power consumption is 1.0 mA (typical at 5.0 V). - What is the operating temperature range of the ADXL1004BCPZ?
The operating temperature range is −40°C to +125°C. - What package type is the ADXL1004BCPZ available in?
The ADXL1004BCPZ is available in a 32-lead LFCSP package (5 mm × 5 mm × 1.80 mm with exposed pad). - Is the ADXL1004BCPZ RoHS compliant?
Yes, the ADXL1004BCPZ is RoHS compliant. - What are some common applications of the ADXL1004BCPZ?
Common applications include condition monitoring, predictive maintenance, asset health monitoring, test and measurement, and bearing fault detection and diagnostics.