Overview
The ADXL1001BCPZ-RL7, produced by Analog Devices Inc., is a high-performance, low-noise, and high-frequency MEMS accelerometer. This device is part of the ADXL1001 series, optimized for industrial condition monitoring and other demanding applications. It features a single in-plane axis accelerometer with an analog output, making it suitable for a wide range of industrial and embedded systems.
The ADXL1001BCPZ-RL7 is known for its ultralow noise density, stable and repeatable sensitivity, and immunity to external shocks up to 10,000 g. It operates over a temperature range of −40°C to +125°C and is packaged in a 5 mm × 5 mm × 1.80 mm LFCSP package, which is RoHS compliant.
Key Specifications
Parameter | Min | Typ | Max | Unit |
---|---|---|---|---|
Measurement Range | ±100 | - | - | g |
Linearity | - | ±0.1 | - | % of full scale |
Cross Axis Sensitivity (ZX) | - | ±1.0 | - | % |
Cross Axis Sensitivity (YX) | - | ±1.0 | - | % |
Sensitivity (Ratiometric to VDD) | - | 20 | - | mV/g |
Sensitivity Change Due to Temperature | - | ±5 | - | % |
Operating Voltage Range | 3.0 | - | 5.25 | V |
Quiescent Supply Current | - | 1.0 | 1.15 | mA |
Standby Current | - | 225 | 285 | µA |
Operating Temperature Range | −40 | - | +125 | °C |
Key Features
- Single in-plane axis accelerometer with analog output
- Linear frequency response range from dc to 11 kHz (3 dB point) and a resonant frequency of 21 kHz
- Ultralow noise density: 30 µg/√Hz in ±100 g range
- Overrange sensing plus dc coupling allows fast recovery time
- Complete electromechanical self-test function
- Sensitivity stability over temperature: ±5%
- Linearity to ±0.1% of full-scale range
- Cross axis sensitivity: ±1% (ZX), ±1% (YX)
- Single-supply operation: 3 V to 5.25 V
- Output voltage ratiometric to supply
- Low power consumption: 1.0 mA
- Power saving standby operation mode with fast recovery
- RoHS compliant
- 5 mm × 5 mm × 1.80 mm LFCSP package
Applications
- Condition monitoring
- Predictive maintenance
- Asset health monitoring
- Test and measurement
- Health usage monitoring system (HUMS)
Q & A
- What is the measurement range of the ADXL1001BCPZ-RL7?
The measurement range of the ADXL1001BCPZ-RL7 is ±100 g.
- What is the noise density of the ADXL1001BCPZ-RL7?
The noise density of the ADXL1001BCPZ-RL7 is 30 µg/√Hz.
- What is the operating voltage range of the ADXL1001BCPZ-RL7?
The operating voltage range is from 3.0 V to 5.25 V.
- What is the quiescent supply current of the ADXL1001BCPZ-RL7?
The quiescent supply current is typically 1.0 mA.
- Does the ADXL1001BCPZ-RL7 have a standby mode?
Yes, it has a power saving standby operation mode with fast recovery.
- What is the temperature range for the ADXL1001BCPZ-RL7?
The operating temperature range is from −40°C to +125°C.
- Is the ADXL1001BCPZ-RL7 RoHS compliant?
Yes, it is RoHS compliant.
- What package type does the ADXL1001BCPZ-RL7 come in?
The device is packaged in a 5 mm × 5 mm × 1.80 mm LFCSP package.
- What are some common applications for the ADXL1001BCPZ-RL7?
Common applications include condition monitoring, predictive maintenance, asset health monitoring, test and measurement, and health usage monitoring system (HUMS).
- Does the ADXL1001BCPZ-RL7 have an integrated self-test function?
Yes, it has a complete electromechanical self-test function.