The ADM1060ARUCS0403R7, produced by Analog Devices Inc., is a programmable supervisory/sequencing device designed to manage multiple power supply fault detection and sequencing in communications systems. This device is particularly useful in central offices, servers, and other infrastructure systems where multiple power supplies are required to power different sections of a board. The ADM1060 ensures that these sections power up in the correct sequence to avoid damage, miscommunication, or latch-up.
Key Specifications
Parameter | Min | Typ | Max | Unit | Test Conditions/Comments |
---|---|---|---|---|---|
High Voltage Supply (VH) | 2 V | - | 14.4 V | V | - |
Positive Voltage Only Supplies (VPn) | 2 V | - | 6 V | V | - |
Bipolar Voltage Supplies (VBn) | -2 V | - | +6 V | V | - |
Watchdog Detector Timeout | 200 ms | - | 12.8 sec | - | Programmable |
General-Purpose Logic Inputs | 4 | - | - | - | - |
Programmable Output Drivers | 9 | - | - | - | Various configurations (open collector, internal pull-up, etc.) |
EEPROM | 256 bytes | - | - | - | User EEPROM |
Interface | - | - | - | - | Industry-standard 2-wire bus interface (SMBus) |
Key Features
- Fault detection on 7 independent supplies, including one high voltage supply, four positive voltage only supplies, and two bipolar voltage supplies.
- Programmable watchdog detector with a timeout delay from 200 ms to 12.8 seconds.
- Four general-purpose logic inputs and a programmable logic block for combinatorial and sequencing logic control.
- Nine programmable output drivers with various configurations (open collector, internal pull-up, etc.).
- 256 bytes of user EEPROM and an industry-standard 2-wire bus interface (SMBus).
Applications
- Central office systems
- Servers
- Infrastructure network boards
- High density, multivoltage system cards
Q & A
- What is the primary function of the ADM1060ARUCS0403R7?
The primary function is to manage multiple power supply fault detection and sequencing in communications systems. - How many independent supplies can the ADM1060 detect faults on?
The device can detect faults on 7 independent supplies. - What is the range of the high voltage supply (VH)?
The high voltage supply (VH) ranges from 2 V to 14.4 V. - What types of output drivers are available on the ADM1060?
The device has 9 programmable output drivers with configurations such as open collector, internal pull-up, and more. - What is the purpose of the watchdog detector?
The watchdog detector monitors a processor clock and can be programmed to detect if the clock does not toggle within a specified time. - How much user EEPROM is available on the ADM1060?
The device has 256 bytes of user EEPROM. - What interface does the ADM1060 use for communication?
The ADM1060 uses an industry-standard 2-wire bus interface (SMBus). - In what types of systems is the ADM1060 typically used?
The ADM1060 is typically used in central office systems, servers, infrastructure network boards, and high density, multivoltage system cards. - Can the ADM1060 be powered by multiple supplies?
Yes, the ADM1060 can be powered by either the VH supply or one of the VPn supplies, whichever is highest. - What is the temperature range for the ADM1060?
The operating temperature range for the ADM1060 is from -40°C to +85°C.