Overview
The ADM1030ARQ, produced by Analog Devices Inc., is an ACPI-compliant two-channel digital thermometer and under/over temperature alarm. It is designed for use in computers and thermal management systems, providing intelligent temperature monitoring and PWM fan control. This component is essential for maintaining optimal system temperatures and ensuring reliable operation in various electronic devices.
Key Specifications
Parameter | Unit | Max | Typ | Min | Test Conditions/Comments |
---|---|---|---|---|---|
Input High Voltage (VIH) | V | 2.1 | |||
Input Low Voltage (VIL) | V | 0.8 | |||
Input High Current (IIH) | μA | 1.0 | VIN = VCC | ||
Input Low Current (IIL) | μA | 1.0 | VIN = 0 | ||
Input Capacitance (CIN) | pF | 5 | |||
Output Low Voltage (VOL) | V | 0.4 | IOUT = –6.0 mA, VCC = 3 V | ||
High Level Output Leakage Current (IOH) | μA | 1.0 | 0.1 | VOUT = VCC | |
VCC Range | V | 3.6 | 3.0 |
Key Features
- ACPI-compliant two-channel digital thermometer
- Under/over temperature alarm functionality
- PWM fan control for thermal management
- Configuration, Address Pointer, Status, Value and Limit, Fan Speed Config, and Offset Registers for detailed control and monitoring
- Serial bus interface for communication
- Support for optimizing temperature readings with offset values
Applications
The ADM1030ARQ is primarily used in computers and thermal management systems to monitor and control temperatures. It is suitable for various applications including:
- Server and data center cooling systems
- High-performance computing systems
- Industrial control systems requiring precise temperature monitoring
- Automotive and aerospace systems where temperature control is critical
Q & A
- What is the primary function of the ADM1030ARQ?
The primary function of the ADM1030ARQ is to serve as a two-channel digital thermometer and under/over temperature alarm, along with PWM fan control for thermal management. - What is the VCC range for the ADM1030ARQ?
The VCC range for the ADM1030ARQ is from 3.0 V to 3.6 V. - How does the ADM1030ARQ communicate with other devices?
The ADM1030ARQ communicates via a serial bus interface. - What types of registers does the ADM1030ARQ have?
The ADM1030ARQ has Configuration, Address Pointer, Status, Value and Limit, Fan Speed Config, and Offset Registers. - Can the temperature readings be optimized on the ADM1030ARQ?
Yes, the temperature readings can be optimized using the Offset Registers, which allow adding or subtracting up to 15°C from a temperature reading. - What is the purpose of the PWM fan control in the ADM1030ARQ?
The PWM fan control is used to regulate fan speed based on temperature readings, ensuring efficient cooling and thermal management. - Is the ADM1030ARQ ACPI-compliant?
Yes, the ADM1030ARQ is ACPI-compliant. - What are some common applications of the ADM1030ARQ?
The ADM1030ARQ is commonly used in computers, server and data center cooling systems, high-performance computing systems, and industrial control systems. - How does the ADM1030ARQ handle under/over temperature alarms?
The ADM1030ARQ has built-in under/over temperature alarm functionality, which alerts the system when temperature limits are exceeded. - Can multiple bytes of data be transferred over the serial bus in one operation?
Yes, any number of bytes of data may be transferred over the serial bus in one operation, but it is not possible to mix read and write operations in one operation.