Overview
The ADF4113HVBRUZ-RL7 from Analog Devices Inc. is an integer-N frequency synthesizer designed for applications requiring high voltage charge pumps and precise frequency control. This device is particularly suited for use with voltage-controlled oscillators (VCOs) that have high tuning voltages, up to 15 V. It features a low noise digital phase frequency detector (PFD), a precision high voltage charge pump, programmable reference and N dividers, and a dual-modulus prescaler. The synthesizer operates with a power supply ranging from 2.7 V to 5.5 V and includes a power-down mode for energy efficiency.
Key Specifications
Parameter | Value | Unit | Test Conditions/Comments |
---|---|---|---|
Power Supply Voltage | 2.7 to 5.5 | V | AVDD = DVDD |
Charge Pump Voltage | Up to 15 | V | VP |
RF Input Frequency Range | 0.2 to 4.0 GHz | GHz | |
Reference Frequency Range | Up to 10 MHz | MHz | fREFIN |
Operating Temperature Range | -40°C to +85°C | °C | B Version |
Digital I/O Voltage | -0.3 V to VDD + 0.3 V | V | |
Analog I/O Voltage | -0.3 V to VP + 0.3 V | V |
Key Features
- High voltage charge pump capable of driving VCOs directly with passive-loop filters
- Low noise digital phase frequency detector (PFD) and precision charge pump
- Programmable reference divider, A and B counters, and dual-modulus prescaler
- Simple 3-wire interface for controlling on-chip registers
- Digital lock detect and power-down mode
- Support for active and passive loop filters using ADIsimPLL™
Applications
- IF/RF local oscillator (LO) generation in base stations and point-to-point radio systems
- Clock generation for analog-to-digital and digital-to-analog converters
- Wireless LANs and PMR (Private Mobile Radio) communications
- Test equipment for communications
- Radar systems for precise frequency control of radar pulses and receiving echoes
Q & A
- What is the operating voltage range of the ADF4113HVBRUZ-RL7?
The device operates with a power supply ranging from 2.7 V to 5.5 V.
- What is the maximum charge pump voltage of the ADF4113HVBRUZ-RL7?
The charge pump voltage can go up to 15 V.
- What is the frequency range of the RF input for the ADF4113HVBRUZ-RL7?
The RF input frequency range is from 0.2 GHz to 4.0 GHz.
- What are the key components of the ADF4113HVBRUZ-RL7?
The device includes a low noise digital phase frequency detector (PFD), a precision high voltage charge pump, programmable reference and N dividers, and a dual-modulus prescaler.
- What are the common applications of the ADF4113HVBRUZ-RL7?
Common applications include IF/RF local oscillator generation, clock generation for converters, wireless LANs, PMR communications, and test equipment.
- How does the ADF4113HVBRUZ-RL7 control its on-chip registers?
The device uses a simple 3-wire interface to control all of the on-chip registers.
- Does the ADF4113HVBRUZ-RL7 support power-down mode?
Yes, the device includes a power-down mode for energy efficiency.
- What is the operating temperature range of the ADF4113HVBRUZ-RL7?
The operating temperature range is from -40°C to +85°C for the B version.
- Can the ADF4113HVBRUZ-RL7 be used with high voltage VCOs?
Yes, the device is designed to drive high voltage VCOs directly with passive-loop filters.
- What tool can be used for loop filter design with the ADF4113HVBRUZ-RL7?
The ADIsimPLL™ tool can be used for loop filter design.