Overview
The ADE7754AR, produced by Analog Devices Inc., is a high-accuracy polyphase electrical energy measurement IC designed for various power meter services. It incorporates second-order sigma-delta ADCs, reference circuitry, a temperature sensor, and comprehensive signal processing capabilities to perform active and apparent energy measurements, as well as rms calculations. This IC is particularly suited for 3-phase/4-wire, 3-phase/3-wire, and 4-wire delta power meter applications. It features a serial interface and a pulse output, making it versatile for different energy measurement needs.
Key Specifications
Parameter | Units | Typical Value | Conditions/Comments |
---|---|---|---|
Active Power Measurement Error | % | 0.1 | Over a dynamic range of 1000 to 1 |
Supply Voltage (AVDD, DVDD) | V | 4.75 to 5.25 | ±5% of 5V |
Input Current (IIN) | mA | ±3 | Typical 10 nA, VIN = 0 V to DVDD |
Input Capacitance (CIN) | pF | 10 | Maximum |
Output High Voltage (VOH) | V | 4 | Minimum, DVDD = 5 V ± 5% |
Output Low Voltage (VOL) | V | 1 | Maximum, DVDD = 5 V ± 5% |
Operating Temperature Range | °C | -40 to +85 | Industrial range |
Power Consumption | mW | 80 | Typical at 5V supply |
Key Features
- High accuracy in active and apparent energy measurements with less than 0.1% error over a dynamic range of 1000:1
- Supports IEC 61036/60687 standards
- Measures active energy, apparent energy, voltage rms, current rms, and sampled waveform data
- On-chip temperature sensor with ±3°C typical accuracy after calibration
- User-programmable thresholds for line voltage SAG and overdrive detections
- SPI compatible serial interface with interrupt request line (IRQ) and pulse output with programmable frequency
- System calibration features including channel offset correction, phase calibration, and gain calibration for each phase
- CF logic output provides instantaneous active power information
- Detection circuit for short duration low or high voltage variations with user-programmable thresholds and duration
- Zero-crossing detection synchronized with the zero-crossing point of the line voltage of each phase
Applications
- 3-phase/4-wire, 3-phase/3-wire, and 4-wire delta power meter services
- Smart energy meters and advanced metering infrastructure (AMI)
- Industrial power monitoring and control systems
- Automated meter reading (AMR) and smart grid applications
- Relay switching and synchronization in power systems
Q & A
- What is the primary function of the ADE7754AR IC?
The ADE7754AR is a polyphase electrical energy measurement IC designed to measure active and apparent energy, voltage rms, and current rms in various power meter services.
- What is the accuracy of the ADE7754AR in active energy measurement?
The ADE7754AR has an accuracy of less than 0.1% in active energy measurement over a dynamic range of 1000:1.
- What communication interface does the ADE7754AR use?
The ADE7754AR uses an SPI compatible serial interface with an interrupt request line (IRQ).
- What is the operating temperature range of the ADE7754AR?
The operating temperature range of the ADE7754AR is -40°C to +85°C.
- Does the ADE7754AR support any specific industry standards?
Yes, the ADE7754AR supports IEC 61036/60687 standards.
- What type of power supply does the ADE7754AR require?
The ADE7754AR requires a single 5V supply with ±5% tolerance.
- What is the purpose of the CF logic output in the ADE7754AR?
The CF logic output provides instantaneous active power information.
- Can the ADE7754AR detect voltage variations?
Yes, the ADE7754AR has a detection circuit for short duration low or high voltage variations with user-programmable thresholds and duration.
- How does the ADE7754AR handle zero-crossing detection?
The ADE7754AR has zero-crossing detection synchronized with the zero-crossing point of the line voltage of each phase.
- What is the typical power consumption of the ADE7754AR?
The typical power consumption of the ADE7754AR is 80 mW at a 5V supply.